Compliance Reports are being audited.
This page will be populated as compliance reports finish that process.
The project is designed to comply with EN14143:2003, EN61508:2004 SIL 4,
ISO/IEC 12207, DNV DN-RP-H101 and NORSOK U100 and U101, each with separate compliance reports.
|
Safety Integrity Level Assignment (151KB)
The safety assessment and assignment of the SIL rating for the different applications for the rebreather.
The eSCR and eCCR was assigned SIL 4+, the comms option SIL 2, independent PPO2 monitor SIL 2, Topside monitoring software SIL 1.
Updated 21st Aug 2007
|
|
Hydrostatic Imbalance Compliance to EN14143:2003 and NORSOK U-101 (11MB)
This is a comprehensive treatise on the theory and practice of hydrostatic imbalance measurement on rebreathers,
and includes the hydrostatic data for Deep Life's Open Revolution family of rebreathers. Comparative data is also
given for the Buddy Inspiration and Draeger Dolphin. The report shows that the Deep Life rebreathers meet
the hydrostatic imbalance requirements of EN14143:2003 and NORSOK U-101 in all configurations: with worst case harness,
worst case backplate, worse case counterlung covers. The configurations tested are of Back Mounted Counterlungs, Front Mounted Counterlungs,
Under-Arm Counterlungs and Over The Shoulder Counterlungs. This achievement is due to the exceptionally low Work Of Breathing
of the equipment, from use of the Micropore EACs, 36mm bore hoses and large section mushroom valves in the mouthpiece.
|
|
Changes for EN61508 Compliance of electronics (249KB)
EN61508 Compliance Reviews identified issues with the electronics, explained in this document, along with the corrections needed to resolve them.
|
| |
|